patch-2.0.34 linux/drivers/scsi/README.aic7xxx

Next file: linux/drivers/scsi/README.in2000
Previous file: linux/drivers/scsi/README.Mylex
Back to the patch index
Back to the overall index

diff -u --recursive --new-file v2.0.33/linux/drivers/scsi/README.aic7xxx linux/drivers/scsi/README.aic7xxx
@@ -1,8 +1,7 @@
 			    AIC7xxx Driver for Linux
-				 April 15, 1996
 
 Introduction
-------------------------
+----------------------------
 The AIC7xxx SCSI driver adds support for Adaptec (http://www.adaptec.com)
 SCSI controllers and chipsets. Major portions of the driver and driver
 development are shared between both Linux and FreeBSD. Support for the
@@ -11,31 +10,42 @@
 2.1.0 or later.
 
   Supported cards/chipsets
-  ------------------------
+  ----------------------------
     Adaptec Cards
-    -----------------------
-    AHA-274x               
-    AHA-2842               
+    ----------------------------
+    AHA-274x
+    AHA-274xT               
+    AHA-2842
+    AHA-2910B               
     AHA-2940               
     AHA-2940W              
     AHA-2940U              
-    AHA-2940UW             
+    AHA-2940UW
+    AHA-2940AU             
     AHA-2944D              
     AHA-2944WD
+    AHA-2944UD
+    AHA-2944UWD
     AHA-3940
+    AHA-3940U
     AHA-3940W
+    AHA-3940UW
     AHA-3985
+    AHA-3985U
     AHA-3985W
+    AHA-3985UW
 
     Motherboard Chipsets
-    -----------------------
+    ----------------------------
     AIC-777x   
     AIC-785x
+    AIC-786x
     AIC-787x
     AIC-788x
+    AIC-7895
 
     Bus Types
-    -----------------------
+    ----------------------------
     W - Wide SCSI, SCSI-3, 16bit bus, 68pin connector, will also support
         SCSI-1/SCSI-2 50pin devices, transfer rates up to 20MB/s.
     U - Ultra SCSI, transfer rates up to 40MB/s.
@@ -49,22 +59,28 @@
     AHA-398x - PCI RAID controllers with three separate SCSI controllers
                on-board.
 
-    NOTE: The AHA-2920 is NOT a AIC-7xxx based controller, and is not
+    NOTE: The AHA-2920 is NOT an AIC-7xxx based controller, and is not
           handled by this driver.
 
   People
-  ------------------------
-    Justin T Gibbs  gibbs@freefall.FreeBSD.org     (BSD Driver Author)
-    Dan Eischen     deischen@iworks.InterWorks.org (Linux Driver Co-maintainer)
-    Dean Gehnert    deang@teleport.com             (Linux FTP/patch maintainer)
-    Jess Johnson    jester@frenzy.com              (AIC7xxx FAQ author)
-
+  ------------------------------
+    Justin T Gibbs  gibbs@plutotech.com
+      (BSD Driver Author)
+    Dan Eischen     deischen@iworks.InterWorks.org
+      (Original Linux Driver Co-maintainer)
+    Dean Gehnert    deang@teleport.com
+      (Original Linux FTP/patch maintainer)
+    Jess Johnson    jester@frenzy.com
+      (AIC7xxx FAQ author)
+    Doug Ledford    dledford@dialnet.net
+      (Current Linux aic7xxx-5.x.x Driver/Patch/FTP/FAQ maintainer)
+    
     Special thanks go to John Aycock (aycock@cpsc.ucalgary.ca), the original
     author of the driver. John has since retired from the project. Thanks
     again for all his work!
-
+    
   Mailing list
-  ------------------------
+  ------------------------------
     There is a mailing list available for users who want to track development
     and converse with other users and developers. This list is for both
     FreeBSD and Linux support of the AIC7xxx chipsets.
@@ -82,13 +98,150 @@
 
     Send regular messages and replies to: AIC7xxx@FreeBSD.ORG
     
-  Command line options
-  ------------------------
+  Boot Command line options
+  ------------------------------
     "aic7xxx=no_reset" -  Eliminate the SCSI reset delay during startup.
         Some SCSI devices need some extra time to reset.
+    "aic7xxx=reverse_scan" - Have the driver register the SCSI cards in the
+        reverse of the normal order.  This may help those people who have more
+        than one PCI Adaptec controller force the correct controller to be
+        scsi0 under linux so that their boot hard drive is also sda under
+        linux
+    "aic7xxx=extended" - Force the driver to detect extended drive translation
+        on your controller.  This helps those people who have cards without
+        a SEEPROM make sure that linux and all other operating systems think
+        the same way about your hard drives.
+    "aic7xxx=irq_trigger:x" - Replace x with either 0 or 1 to force the kernel
+        to use the correct IRQ type for your card.  This only applies to EISA
+        based controllers.  On these controllers, 0 is for Edge triggered
+        interrupts, and 1 is for Level triggered interrupts.  If you aren't
+        sure or don't know which IRQ trigger type your EISA card uses, then
+        let the kernel autodetect the trigger type.
+    "aic7xxx=verbose" - This option can be used in one of two ways.  If you
+        simply specify aic7xxx=verbose, then the kernel will automatically pick
+        the default set of verbose messages for you to see.  Alternatively, you
+        can specify the command as "aic7xxx=verbose:0xXXXX" where the X entries
+        are replaced with hexadecimal digits.  This option is a bit field type
+        option.  For a full listing of the available options, search for the
+        #define VERBOSE_xxxxxx lines in the aic7xxx.c file.  If you want verbose
+        messages, then it is recommended that you simply use the aic7xxx=verbose
+        variant of this command.
+    "aic7xxx=7895_irq_hack:x" - This option enables some work around code to
+        fix a bug in the Tyan Thunder II motherboard BIOS.  The BIOS
+        incorrectly sets the IRQs on the two channels of the 7895 to two
+        different values even though the motherboard hardware doesn't support
+        this mode of operation.  The valid values for x are: 0 to force
+        both channels to use the IRQ assigned to Channel A, 1 to force both
+        channels to use the IRQ assigned to Channel B, and -1 will disable
+        this horrible abomination of a hack.  The default is disabled (-1).
+    "aic7xxx=tag_info:{{8,8..},{8,8..},..}" - This option is used to enable
+        tagged queueing on specific devices.  As of driver version 5.0.6, we
+        now globally enable tagged queueing by default, but we also disable
+        tagged queueing on all individual devices by default.  In order to
+        enable tagged queueing for certian devices at boot time, a user may
+        use this boot param.  The driver will then parse this message out
+        and enable the specific device entries that are present based upon
+        the value given.  The param line is parsed in the following manner:
+
+          { - first instance indicates the start of this parameter values
+              second instance is the start of entries for a particular
+              device entry
+          } - end the entries for a particular host adapter, or end the entire
+              set of parameter entries
+          , - move to next entry.  Inside of a set of device entries, this
+              moves us to the next device on the list.  Outside of device
+              entries, this moves us to the next host adapter
+          . - Same effect as , but is safe to use with insmod.
+          x - the number to enter into the array at this position.  
+              0 = Enable tagged queueing on this device and use the default
+                  queue depth
+              1-254 = Enable tagged queueing on this device and use this
+                      number as the queue depth
+              255 = Disable tagged queueing on this device.
+              Note: anything above 32 for an actual queue depth is wasteful
+                    and not recommended.
+
+        A few examples of how this can be used:
+
+        tag_info:{{8,12,,0,,255,4}}
+          This line will only effect the first aic7xxx card registered.  It
+          will set scsi id 0 to a queue depth of 8, id 1 to 12, leave id 2
+          at the default, set id 3 to tagged queueing enabled and use the
+          default queue depth, id 4 default, id 5 disabled, and id 6 to 4.
+          Any not specified entries stay at the default value, repeated
+          commas with no value specified will simply increment to the next id
+          without changing anything for the missing values.
+
+        tag_info:{{8,8},,{8,8}}
+          First adapter, scsi id 0 to 8, id 1 to 8, remainder stay at their
+          default.  Second adapter stays entirely at default.  Third
+          adapter, id 0 to 8, id 1 to 8, remainder at default (identical to
+          first adapter).
+
+        tag_info:{,,,{,,,64}}
+          First, second, and third adapters at default values.  Fourth
+          adapter, id 3 to 64.  Notice that leading commas simply increment
+          what the first number effects, and there are no need for trailing
+          commas.  When you close out an adapter, or the entire entry,
+          anything not explicitly set stays at the default value.
+
+        A final note on this option.  The scanner I used for this isn't
+        perfect or highly robust.  If you mess the line up, the worst that
+        should happen is that the line will get ignored.  If you don't
+        close out the entire entry with the final bracket, then any other
+        aic7xxx options after this will get ignored.  So, in general, be
+        sure of what you are entering, and after you have it right, just
+        add it to the lilo.conf file so there won't be any mistakes.  As
+        a means of checking this parser, the entire tag_info array for
+        each card is now printed out in the /proc/scsi/aic7xxx/x file.  You
+        can use that to verify that your options were parsed correctly. 
+        
+    Boot command line options may be combined to form the proper set of options
+    a user might need.  For example, the following is valid:
+    
+    aic7xxx=verbose,extended,irq_trigger:1
+    
+    The only requirement is that individual options be separated by a comma on
+    the command line.
+        
+  Module Loading command options
+  ------------------------------
+    When loading the aic7xxx driver as a module, the exact same options are
+    available to the user.  However, the syntax to specify the options changes
+    slightly.  For insmod, you need to wrap the aic7xxx= argument in quotes
+    and replace all ',' with '.'.  So, for example, a valid insmod line
+    would be:
+
+    insmod aic7xxx aic7xxx='verbose.irq_trigger:1.extended'
+
+    This line should result in the *exact* same behaviour as if you typed
+    it in at the lilo prompt and the driver was compiled into the kernel
+    instead of being a module.  The reason for the single quote is so that
+    the shell won't try to interpret anything in the line, such as {. 
+    Insmod assumes any options starting with a letter instead of a number
+    is a character string (which is what we want) and by switching all of
+    the commas to periods, insmod won't interpret this as more than one
+    string and write junk into our binary image.  I consider it a bug in
+    the insmod program that even if you wrap your string in quotes (quotes
+    that pass the shell mind you and that insmod sees) it still treates
+    a comma inside of those quotes as starting a new variable, resulting
+    in memory scribbles if you don't switch the commas to periods.
+
+
+  Kernel Compile options
+  ------------------------------
+    The various kernel compile time options for this driver are now fairly
+    well documented in the file Documentation/Configure.help.  In order to
+    see this documentation, you need to use one of the advanced configuration
+    programs (menuconfig and xconfig).  If you are using the "make menuconfig"
+    method of configuring your kernel, then you would simply highlight the
+    option in question and hit the F1 key.  If you are using the "make xconfig"
+    method of configuring your kernel, then simply click on the help button next
+    to the option you have questions about.  The help information from the
+    Configure.help file will then get automatically displayed.
 
   /proc support
-  ------------------------
+  ------------------------------
     The /proc support for the AIC7xxx can be found in the /proc/scsi/aic7xxx/
     directory. That directory contains a file for each SCSI controller in
     the system. Each file presents the current configuration and transfer
@@ -98,12 +251,12 @@
     Matthew Jacob for statistics support.
 
   FTP sites
-  ------------------------
-    ftp://ftp.teleport.com/users/deang/Linux/aic7xxx/
-      - Main Linux AIC7xxx driver release/pre-release site
-      - Experimental/development patches and bootdisks
+  ------------------------------
     ftp://ftp.dialnet.net/pub/linux/aic7xxx/
+      - Primary site for Doug Ledford developed driver releases
       - US Linux mirror of Teleport site
+    ftp://ftp.pcnet.com/users/eischen/Linux/
+      - Dan Eischen's driver distribution area
     ftp://ekf2.vsb.cz/pub/linux/kernel/aic7xxx/ftp.teleport.com/
       - European Linux mirror of Teleport site
 
@@ -113,3 +266,4 @@
 
 $Revision: 3.0 $
 
+Modified by Doug Ledford 1998

FUNET's LINUX-ADM group, linux-adm@nic.funet.fi
TCL-scripts by Sam Shen, slshen@lbl.gov